View Analysis
AC ANTI-RECEPTEURS de la TSH


General informations


Name :
AC ANTI-RECEPTEURS de la TSH
LIS code :
XXRTSH
Synonyms

Anti-TSHR, TRAK

NABM reference :
THYROIDE : AUTOAC ANTIRECEPTEURS DE TSH
Created :
24/09/2014
Updated :
17/11/2023
Category :
Thyroïde
Frequency :
5/s
Technical sector :
Immuno-enzymologie
Mother analysis :
-
Volume needed :
1 mL
Technical delay :
unspecified
Sample :
Sec-gel (7ml total - 5ml av)
Additive :
GEL
Sérotèque :
No
Fasting :
No
Cotation :
79 B
Price :
21.33


Alternative sample :
-

Additional details :
Biologistes responsables: C. Martaresche et M. Mari

Preservations


global.conservationToLab


3 D

Processing locations


  • Barla

Comments


Technical informations


Method :
Electrochimiluminescence
Reference values :
0 - 1.75 UI/L
Linear limits :
0.8 - 40 UI/L
Automate / Manual operation :
Roche Cobas e
Analytic sensibility :
0.8 UI/L
Functional sensibility :
0.8UI/L

Additional informations


HPRIM code :
RTSH_1
Nature code :
2
Result type :
numérique
Technical timeframe minutes :
-
LOINC :
Immunology > Autoimmunity EIA > Thyrotropin receptor Ab [Units/volume] in Serum By Immunoassay — 57416-0
Result decimals :
2
Result unit :
UI/L

Transport conditions


  • Sachet Vert

Response codes


Complementary informations


Pre-analytic advice :
Chez les patients traités par de fortes doses de biotine (> 5 mg/jour), il est
recommandé d’effectuer le prélèvement de l’échantillon au moins 8 heures
après la dernière administration.
Post-analytic advice :

Interferences :
« ** Attention ! Il existe une interférence possible chez les patients traités par de fortes doses de biotine. En cas de discordance clinico-biologique, il est recommandé d’effectuer le prélèvement au moins 24 heures après la dernière administration de complément alimentaire à fortes doses. En cas de traitement par Qizenday, un contrôle après une semaine d’arrêt de traitement ou par une technique différente est recommandé.».

Documents


url